Back to home page
Majordomo MF (Multi Flow) for apartment buildings with supply/inlet valves without MVHR system
The air separator. Add up to 50% to system efficiency
Improves air quality by maintaining comfortable CO2 and humidity levels
Increases service intervals in ventilation system maintenance
Reduces the initial cost of purchasing and installing a ventilation system
Reduces heating costs
Majordomo MF increases the energy efficiency of the ventilation system with a communal exhaust fan
Majordomo MF algorithm together with the control device and integration into the general ventilation system performs the task of sorting and redistribution of air flows individually, inside each room of each apartment of the apartment building depending on the intensity of use of the rooms.
Majordomo MF is a solution to enhance the quality of life even if an apartment building cannot be equipped with a shared or individual heat recovery system
Majordomo MF is used in apartment buildings when common professional equipment (fan with pressure sensor, heat pump, etc.) is placed on one common ventilation shaft on the roof, and only Majordomo MF is placed in each apartment without fan control, but with fresh air supply through supply dampers.
Thus our system regulates the air flow in each apartment and closes the dampers when fresh air is not needed, and the fan on the roof has a pressure sensor and regulates the speed and volume of the extracted air.
Thus our system regulates the air flow in each apartment and closes the dampers when fresh air is not needed, and the fan on the roof has a pressure sensor and regulates the speed and volume of the extracted air.
Approximate calculation of the payback of the system
Apartment building with one common exhaust unit on the roof or in the technical room for 20 apartments.
Costs
Price and installation of Majordomo MF system
€2000 * 20 = €40,000
Savings
Savings on changing filters in the recuperator 2 calls to the master + filters, per year
€200 * 20 = €4000
Savings on heating, approximately 15%, per year
€400 * 20 = €8000
Savings on the initial cost of the total recuperator system
from €10,000
Total
Savings per year more than
€12,000
Total
Savings on start-up costs
€10,000
Total
Payback is less than
3 year
Struggling to reduce the cost of running your home?
Contact us to find out how Majordomo can solve your specific challenge
Installation and Maintenance
Easy installation
A qualified installer can install the Majordomo Multi Flow system without the need for special training.
Detailed instructions
Each device comes with a detailed step-by-step instruction. It is necessary to select the required operating mode by jumper on the board according to the instruction under the cover. The device is set up and calibrated independently, no additional adjustment is required.
Cost-neutral maintenance
The unit requires no regular maintenance, just what you do as part of your general ventilation system maintenance. No consumables or annual maintenance fees.
Specifications and documents
Technical
specifications
Maximum volume of air extracted through the system . . . . . . . . . . . . . .
Up to 300 m3/h
Housing material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ABS plastic
System power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
220V 50 Gh
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12V
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Touch screen, wired
Connecting ductwork: room/toilet/bathroom/kitchen . . . . . . . . . . . . . . .
Ø 100, Ø 125
Connecting ductwork: shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ø 125
Type of connected fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
There is no fan control
Weight of the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3,6 kg
Download product documentation
Specifications and documents
Technical
specifications
Maximum volume of air extracted through the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Up to 300 m3/h
Housing material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ABS plastic
System power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . .
220V 50 Gh
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12V
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Touch screen, wired
Connecting ductwork: room/toilet/bathroom/kitchen . . . . . . . . . . . . . . . . . . . .
Ø 100, Ø 125
Connecting ductwork: shaft . . . . . . . . . . . . . . . . . . . . . .
Ø 125
Type of connected fan . . . . . . . . . . . . . . . . . . . . . . . . . . .
There is no fan control
Weight of the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3,6 kg
Download product documentation
Specifications and documents
Technical
specifications
Maximum volume of air extracted
through the system
through the system
Up to 300 m3/h
Housing material
ABS plastic
System power supply
220V 50 Gh
Power supply
12V
Control panel
Touch screen, wired
Connecting ductwork: room
Ø 100, Ø 125
Connecting ductwork: connected
to the recuperator/ventilator
to the recuperator/ventilator
Ø 125
Type of connection to HRV system
Cable, through MODBUS
Weight of the device
3,6