Majordomo HF (Heat Flow) for apartment in condo with central MVHR system
MVHR Booster. Add up to 50% to system efficiency
Improves air quality by maintaining comfortable CO2 and humidity levels
Increases the service life of the MVHR-system and reduces its maintenance costs (filter replacement)
Reduces the cost of purchasing and installing a ventilation system
Reduces household costs
Majordomo HF increases MVHR-system efficiency
The air quality control system consists of a control device with Majordomo HF algorithm and a building-wide recuperator designed to sort and redistribute ventilation flows in all rooms of all apartments in the apartment building.
Majordomo HF is used in multi-family buildings, when a single common equipment (fans with pressure sensor, MVHR-system) is used in the technical room or on the roof.
Only Majordomo HF is installed in each apartment, which in turn controls only the air flow inside the apartment. Thus, our system regulates the air flow in each apartment and closes the dampers when the air is not needed, while the common equipment maintains the pressure in the system and regulates the speed of air supply and exhaust.
When building occupants do not need to actively ventilate the rooms of their own apartment (e.g. during work and study hours), and the exhaust system reduces its performance, helping to keep the heat inside the house. As activity within the apartments increases (as identified through changes in room indicators), the Majordomo HF algorithm will open the necessary dampers, thereby changing the air pressure in the common shaft. In this case, the speed of the communal fans increases and indoor air quality is quickly restored.
The waste heat is recovered by the heat recovery system in the building, which has a significant impact on savings.
When building occupants do not need to actively ventilate the rooms of their own apartment (e.g. during work and study hours), and the exhaust system reduces its performance, helping to keep the heat inside the house. As activity within the apartments increases (as identified through changes in room indicators), the Majordomo HF algorithm will open the necessary dampers, thereby changing the air pressure in the common shaft. In this case, the speed of the communal fans increases and indoor air quality is quickly restored.
The waste heat is recovered by the heat recovery system in the building, which has a significant impact on savings.
Approximate calculation of the payback of the system
Multi-family building with one shared MVHR system for 20 apartments.
Costs
Price and installation of Majordomo HF system
€2000 * 20 = €40,000
Savings
Savings on changing filters in the recuperator 2 calls to the master + filters, per year
€200 * 20 = €4000
Savings on the initial cost of the total recuperator system
from €10,000
Total
Savings per year more than
€12,000
Total
Savings on start-up costs
€10,000
Total
Payback is less than
3 year
Struggling to reduce the cost of running your home?
Contact us to find out how Majordomo can solve your specific challenge
Installation and Maintenance
Easy installation
With Majordomo Heat Flow installation is carried out by appropriately qualified professionals according to the project.
Detailed instructions
Each device comes with a detailed step-by-step instruction. It is necessary to select the required operating mode by jumper on the board according to the instruction under the cover. The device is set up and calibrated independently, no additional adjustment is required.
Cost-neutral maintenance
The unit requires no regular maintenance, just what you do as part of your general ventilation system maintenance. No consumables or annual maintenance fees.
Specifications and documents
Technical
specifications
Maximum volume of air extracted through the system . . . . . . . . . . . . . .
Up to 300 m3/h
Housing material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ABS plastic
System power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
220V 50 Gh
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12V
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Touch screen, wired
Connecting ductwork: room/toilet/bathroom/kitchen . . . . . . . . . . . . . . .
Ø 100
Connecting ductwork: HRV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 x Ø 125
Type of connection to HRV system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
There is no HRV control
Weight of the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3,6 kg
Download product documentation
Specifications and documents
Technical
specifications
Maximum volume of air extracted through the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Up to 300 m3/h
Housing material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ABS plastic
System power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . .
220V 50 Gh
Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12V
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Touch screen, wired
Connecting ductwork: room/toilet/bathroom/kitchen . . . . . . . . . . . . . . . . . . . .
Ø 100
Connecting ductwork: HRV . . . . . . . . . . . . . . . . . . . . . .
2 x Ø 125
Type of connection to HRV system . . . . . . . . . . . . . . .
There is no HRV control
Weight of the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3,6 kg
Download product documentation
Specifications and documents
Technical
specifications
Maximum volume of air extracted
through the system
through the system
Up to 300 m3/h
Housing material
ABS plastic
System power supply
220V 50 Gh
Power supply
12V
Control panel
Touch screen, wired
Connecting ductwork: room
Ø 100, Ø 125
Connecting ductwork: connected
to the recuperator/ventilator
to the recuperator/ventilator
Ø 125
Type of connection to HRV system
Cable, through MODBUS
Weight of the device
3,6